I’m syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat and I noticed that one of the disks consistently shows less than half the write IOPS of the other:

                                        capacity     operations     bandwidth 
pool                                  alloc   free   read  write   read  write
------------------------------------  -----  -----  -----  -----  -----  -----
storage-volume-backup                 5.03T  11.3T      0    867      0   330M
  mirror-0                            5.03T  11.3T      0    867      0   330M
    wwn-0x5000c500e8736faf                -      -      0    212      0   164M
    wwn-0x5000c500e8737337                -      -      0    654      0   165M

This is also evident in iostat:

     f/s f_await  aqu-sz  %util Device
    0.00    0.00    3.48  46.2% sda
    0.00    0.00    8.10  99.7% sdb

The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.

Is this behaviour expected?

  • lightrush@lemmy.caOP
    link
    fedilink
    English
    arrow-up
    2
    ·
    4 months ago

    Turns out the on-CPU SATA controller isn’t available when the NVMe slot is used. 🫢 Swapped SATA ports, no diff. Put the low IOPS disk in a good USB 3 enclosure, hooked to an on-CPU USB controller. Now things are flipped:

                                            capacity     operations     bandwidth 
    pool                                  alloc   free   read  write   read  write
    ------------------------------------  -----  -----  -----  -----  -----  -----
    storage-volume-backup                 12.6T  3.74T      0    563      0   293M
      mirror-0                            12.6T  3.74T      0    563      0   293M
        wwn-0x5000c500e8736faf                -      -      0    406      0   146M
        wwn-0x5000c500e8737337                -      -      0    156      0   146M